Tripp Lite PDUMH15HVATNET 2.4kW Single-Phase Switched Automatic Transfer Switch PDU, Two 200-240V C14 Inlets, 10 C13 Outputs, 1U, TAA

  • Brand : Tripp Lite
  • Product name : PDUMH15HVATNET 2.4kW Single-Phase Switched Automatic Transfer Switch PDU, Two 200-240V C14 Inlets, 10 C13 Outputs, 1U, TAA
  • Product code : PDUMH15HVATNET
  • GTIN (EAN/UPC) : 0037332197504
  • Category : Power Distribution Units (PDUs)
  • Data-sheet quality : created/standardized by Icecat
  • Product views : 69325
  • Info modified on : 22 Apr 2024 13:01:31
  • Product Brochure/Datasheet (0.0 MB)
  • Bullet Points Tripp Lite PDUMH15HVATNET 2.4kW Single-Phase Switched Automatic Transfer Switch PDU, Two 200-240V C14 Inlets, 10 C13 Outputs, 1U, TAA :
    • - 8 switched and 2 unswitched 200-240V C13 outlets distribute power to connected equipment
    • - Pre-installed WEBCARDLX with latest version of PADM20 for IP-based Auto Probe feature
    • - Remote power monitoring and control reduces on-site visits and maintenance costs
    • - Dual 12-ft. (3.66 m) input cords with C14 plugs connect to separate primary/secondary power sources
    • - Mounts horizontally in 1U of space in common 19 in. racks for easy installation
  • Warranty: : 2-year limited
  • Long product name Tripp Lite PDUMH15HVATNET 2.4kW Single-Phase Switched Automatic Transfer Switch PDU, Two 200-240V C14 Inlets, 10 C13 Outputs, 1U, TAA :

    2.4kW Single-Phase Switched Automatic Transfer Switch PDU, Two 200-240V C14 Inlets, 10 C13 Outputs, 1U, TAA

  • Tripp Lite PDUMH15HVATNET 2.4kW Single-Phase Switched Automatic Transfer Switch PDU, Two 200-240V C14 Inlets, 10 C13 Outputs, 1U, TAA :

    2-2.4kW Single-Phase ATS rack PDU (rPDU) with Primary and Secondary Inputs for Power Redundancy
    Recommended for data centers, server rooms and network closets, this 1U switched power distribution unit enables redundant A/B power for network devices with single power cords. Dual 12-ft. (3.7 m) input cords with C14 plugs connect to separate primary and secondary mains circuits, backup generators, UPS systems or utility power grids. Plug-lock insert sleeves are included to prevent connected cords from becoming accidentally dislodged. The PDUMH15HVATNET constantly evaluates the power quality of both input sources and maintains continuous power to all outlets as derived from the primary source.

    Switches from Primary to Secondary Power Source in Milliseconds
    Dynamic solid-state automatic transfer switching (ATS) allows the IEC C13 PDU to switch to the secondary source within 2-5 milliseconds, should the primary source fail or become unstable, to ensure your connected equipment operates without interruption.
    An on-board ATS processor prevents switching if the secondary source is unavailable or of lower quality than the primary source.

    Switched C13 Outlets Are Individually Controllable for Remote Reboots and Load Shedding
    This switched power distribution unit distributes, monitors and manages selectable 200-240V power to equipment in network applications requiring individual outlet control, load shedding and remote monitoring of critical network components. Eight switched C13 outlets (two additional C13 outlets are unswitched) are subject to advanced network control and remote power monitoring, including the ability to turn on, turn off, reboot or lock out power to each outlet. Reducing the frequency of on-site visits can save you money and reduce downtime, thus lowering the PDU's total cost of ownership.

    Check Essential Functions at a Glance
    A front-panel digital load meter displays total PDU output current in amps. LEDs indicate on/off status of individual outlets and power status of primary and secondary inputs. An input-voltage select switch lets you toggle between high (220, 230 or 240V) or low (200 or 208V) voltage.

    Built-In LX Platform Interface Gives You Unrestricted Remote Access to Your Equipment 24/7
    The built-in WEBCARDLX with the latest version of PowerAlert Device Manager firmware (PADM20) provides enhanced remote management capabilities, including customizable dashboard graphs to fit user preferences. The PADM20 upgrade and PowerAlert Element Manager (PAEM) software form a powerful tool for expanding maintenance functions in large installations, including firmware update checks and backup and restoration of device configurations. PADM20’s Auto Probe feature allows a PDU with switched loads to automatically reboot devices if a network communication failure is detected. This preserves uptime and minimizes the time and expense associated with on-site support.

    Easy to Install Horizontally in an EIA-Standard 19 in. Rack
    This ATS PDU mounts in 1U of space in 19-inch rack or rack cabinet using the included brackets and hardware.

    TAA-Compliant for GSA Schedule Purchases
    The PDUMH15HVATNET is compliant with the Federal Trade Agreements Act (TAA), which makes it eligible for GSA (General Services Administration) Schedule and other federal procurement contracts.

  • Short summary description Tripp Lite PDUMH15HVATNET 2.4kW Single-Phase Switched Automatic Transfer Switch PDU, Two 200-240V C14 Inlets, 10 C13 Outputs, 1U, TAA :

    Tripp Lite PDUMH15HVATNET 2.4kW Single-Phase Switched Automatic Transfer Switch PDU, Two 200-240V C14 Inlets, 10 C13 Outputs, 1U, TAA, Monitored, Switched, 1U, Horizontal, Black, 10 AC outlet(s), C13 coupler

  • Long summary description Tripp Lite PDUMH15HVATNET 2.4kW Single-Phase Switched Automatic Transfer Switch PDU, Two 200-240V C14 Inlets, 10 C13 Outputs, 1U, TAA :

    Tripp Lite PDUMH15HVATNET 2.4kW Single-Phase Switched Automatic Transfer Switch PDU, Two 200-240V C14 Inlets, 10 C13 Outputs, 1U, TAA. PDU types: Monitored, Switched, Rack capacity: 1U, Mounting: Horizontal. AC outlets quantity: 10 AC outlet(s), AC outlet types: C13 coupler, Power plug: IEC 320. Cable length: 3.6 m, Certification: TAA. Nominal input voltage: 200-240 V, Maximum current: 10 A, Nominal output voltage: 200-240 V. Width: 440.2 mm, Depth: 367 mm, Height: 43.4 mm

Specs
Design
PDU types Monitored, Switched
Rack capacity 1U
Mounting Horizontal
Product colour Black
Ports & interfaces
AC outlets quantity 10 AC outlet(s)
Power plug IEC 320
AC outlet types C13 coupler
Features
Cable length 3.6 m
Certification TAA
Power
Nominal input voltage 200-240 V
Maximum current 10 A
Nominal output voltage 200-240 V
Maximum power 2400 W
Weight & dimensions
Width 440.2 mm
Depth 367 mm

Weight & dimensions
Height 43.4 mm
Weight 4.72 kg
Packaging data
Package weight 7.1 kg
Package width 515.1 mm
Package depth 579.9 mm
Package height 110 mm
Operational conditions
Operating temperature (T-T) -15 - 50 °C
Storage temperature (T-T) -15 - 60 °C
Operating relative humidity (H-H) 5 - 95%
Operating altitude 0 - 3000 m
Technical details
Sustainability certificates RoHS
Logistics data
Country of origin Taiwan
Products per master (outer) case 1 pc(s)
Similar products
Product: PDUMH30-ISO
Product code: PDUMH30-ISO
Stock:
Price from: 0(excl. VAT) 0(incl. VAT)
Product: PDUMH20ATS
Product code: PDUMH20ATS
Stock:
Price from: 0(excl. VAT) 0(incl. VAT)
Product code: PDUMH15ATS
Stock:
Price from: 0(excl. VAT) 0(incl. VAT)
Product code: PDUMNH20AT1
Stock:
Price from: 0(excl. VAT) 0(incl. VAT)
Product code: PDUMNH15AT1
Stock:
Price from: 0(excl. VAT) 0(incl. VAT)
Product code: PDUBHV101U
Stock:
Price from: 0(excl. VAT) 0(incl. VAT)
Distributors
Country Distributor
4 distributor(s)
2 distributor(s)
1 distributor(s)